KLU 100 |
Ranges
humidity : 0...100 % RH
temperature : -50…+50°C
Accuracy
humidity : +/-2 %RH(0…90 %RH / 25°C)
temperature : +/- 0.5°C / 0°C
|
 |
|
PS500 |
Measurement range (Pa) : 30...500 Pa
Accuracy (at applied pressure) : PS500: ± 5 Pa
Environment:
Operating temperature: -20...60 °C
Storage temperature: -20...85 °C
Humidity: 0 to 95 % rH, non condensing |
 |
|
SMD100 |
입력 전원 : 24 VDC/VAC, 220VAC (110VAC:Optional)
출 력
저전압 Relay 접점(2A@30VDC/VAC) - SPST
고전압 Realy 접점(5A@30VDC/277VAC) - DPDT
Trouble Relay접점(2A@ 32VDC/VAC) - SPST(Optional)
동작온도범위 0~50.0℃
동작습도범위 5~95% RH
초기화 기능 : 초기화 RESET 버튼
LED 표시 기능
전원-녹색LED(PCB), 연기감지기 센서 - 적색LED |
 |
|
RADON Transmitter |
Measurementprinciple : Diffusion to high voltage measurement chamber
Detection principal : Alpha spectroscopy
assurement Range : 0-1000 Bq/m3 ... 0-10MBq/m³ |
 |
|
90-7A / 90-7B |
Output voltage: 0 .. 265 VAC
Frequency: 50 Hz
Power: 1000 VA / 3500 VA
Deviation: ± 1% of setting
Adjustment: electromechanical
Adjustment speed: max. 50 V/s
Load: fully inductive/capacitive
Interface: digital , Analog interface
Line voltage: 230 VAC ± 10%; 49 .. 61 Hz
Weight: 90-7A: 17 kg
90-7B: 31 kg |
 |